We have collected the most relevant information on Pulseaudio Default Sample Format. Open the URLs, which are collected below, and you will find all the info you are interested in.
Alternate sample rates - Arun Raghavan
https://arunraghavan.net/2011/10/alternate-sample-rates/#:~:text=Currently%2C%20PulseAudio%20runs%20all%20your%20devices%20at%20a,sample%20rates%20are%20resampled%20to%20this%20sample%20rate.
PulseAudio: Sample Format Specifications
https://freedesktop.org/software/pulseaudio/doxygen/sample.html
PulseAudio default sample format : linuxaudio
https://www.reddit.com/r/linuxaudio/comments/rlrxz9/pulseaudio_default_sample_format/
PulseAudio default sample format This has probably been asked a thousand times, so I apologize. In daemon.conf, does default-sample-format refer to the format that Pulseaudio outputs to the card, or the format it uses for internal processing?
pulse-daemon.conf - man pages section 5: File Formats - Oracle
https://docs.oracle.com/cd/E88353_01/html/E37852/pulse-daemon-conf-5.html
rlimit-rttime Defaults to 1000000. DEFAULT DEVICE SETTINGS Most drivers try to open the audio device with these settings and then fall back to lower settings. The default settings are CD quality: 16bit native endian, 2 channels, 44100 Hz sampling. default-sample-format= The default sampling format.
Choosing the Right PulseAudio Default Sample Format ...
https://www.reddit.com/r/linuxquestions/comments/rxx8dw/choosing_the_right_pulseaudio_default_sample/
Choosing the Right PulseAudio Default Sample Format. I'm using onboard sound card with Realtek ALC3234 Codec. Here are relevant information found in /proc/asound/card0/codec#0: Codec: Realtek ALC3234 Vendor Id: 0x10ec0255 Subsystem Id: 0x10280725 Revision Id: 0x100002 Default PCM: rates [0x560]: 44100 48000 96000 192000 bits [0xe]: 16 20 24 formats …
PulseAudio - LinuxReviews
https://linuxreviews.org/PulseAudio
default-sample-rate sets the default sample-rate used by PulseAudio. Modern digital audio equipment can usually handle 48000 just fine. Using 96000 would also be fine if you only use a external DAC/AMP connected by USB or motherboard audio. HDMI outputs on modern GPUs do not support anything higher than 48000.
PulseAudio/Examples - ArchWiki - Arch Linux
https://wiki.archlinux.org/title/PulseAudio/Examples
# Default default-sample-channels=2 # For 5.1 default-sample-channels=6 # For 7.1 default-sample-channels=8 If your channels are not correclty mapped or the volume controls for the individual channels do not work as expected in pavucontrol, and you have a HDMI and an analog soundcard, then try to add the following line to /etc/pulse/default.pa
Audiophile – PulseAudio
https://www.freedesktop.org/wiki/Software/PulseAudio/Documentation/User/Audiophile/
By default, PulseAudio (PA) uses very conservative settings. This will work fine for most audio media as you will most likely have 44,100Hz sample rate files. However, if you have higher sample rate recordings it is recommended that you increase the sample rate that PA uses. In /etc/pulse/daemon.conf add: default-sample-format = s32le default-sample-rate = 96000.
Setting the default ALSA device for Pulseaudio - Ask Ubuntu
https://askubuntu.com/questions/294512/setting-the-default-alsa-device-for-pulseaudio
You can change that in /etc/pulse/default.conf ( alternate-sample-rate = 96000, default-sample-format=s24-32le ). This will lead to greater CPU usage, though. This is a bit of a silly situation, having to apply global configuration for all devices. We're planning to add per-device configuration at some point.
pulse-daemon.conf: PulseAudio daemon configuration …
https://www.systutorials.com/docs/linux/man/5-pulse-daemon.conf/
If left unspecified or is set to 0 it will default to some system-specific default, usually 64 MiB. Please note that usually there is no need to change this value, unless you are running an OS kernel that does not do memory overcommit. lock-memory= Locks …
PulseAudio - Official Kodi Wiki
https://kodi.wiki/index.php?title=PulseAudio
default-sample-format = s24le default-sample-rate = 44100 alternate-sample-rate = 48000 ;new with pulseaudio 11 avoid-resampling = true resample-method = speex-float-5 Some remark: This will actively make passthrough non working, as we need s16le format for adding ac3 / dts / etc. to the sink.
Now you know Pulseaudio Default Sample Format
Now that you know Pulseaudio Default Sample Format, we suggest that you familiarize yourself with information on similar questions.