The difference between AIS and RAI alarms on a T1

    https://calix.force.com/CalixCommunity/s/article/The-difference-between-AIS-and-RAI-alarms-on-a-T1-1#:~:text=RAI%20%3D%20Remote%20Alarm%20Indication.%20The%20T1%20will,by%208%20SPACES%20%280%29%20in%20the%20Datalink%20bits.
    none

Performance Monitoring and Alarm Guide - AudioCodes

    https://www.audiocodes.com/media/10596/ltrt-94954-mediant-1000b-gateway-and-e-sbc-performance-monitoring-and-alarm-guide-ver-70.pdf
    Version 7.0 7 Performance Monitoring and Alarms Performance Monitoring and Alarm Guide Notices Notice This document describes the Performance Monitoring parameters and alarms for the Mediant 1000B Gateway and E-SBC product. Information contained in this document is believed to be accurate and reliable at the time of printing.

Trunk RAI Alarms in Audiocodes M2K - Nortel: CS1000 ...

    https://www.tek-tips.com/viewthread.cfm?qid=1729670
    Trunk RAI Alarms in Audiocodes M2K - Nortel: CS1000 (Meridian) systems - Tek-Tips. Home. Forums. Wiring Closet. Phone and Telephony Systems. Nortel: CS1000 (Meridian) systems Forum.

One Voice Operations Center Alarms Guide - …

    https://www.audiocodes.com/media/11983/ltrt-41606-one-voice-operations-center-alarms-guide-ver-74.pdf
    Alarms Guide . AudioCodes One Voice™ Operations Center . Managed Devices and Endpoints . Version 7.4

Mediant™ 1000B Gateway & E-SBC - AudioCodes

    https://www.audiocodes.com/media/13746/mediant-1000b-gateway-e-sbc-quick-guide.pdf
    RAI (Remote Alarm Indication - Yellow Alarm) Off Failure or disruption in power supply or power is not being supplied to the device through the power supply entry. ... AudioCodes Ltd. (NASDAQ, TASE: AUDC) is a leading vendor of advanced communications software, products and

The difference between AIS and RAI alarms on a T1

    https://calix.force.com/CalixCommunity/s/article/The-difference-between-AIS-and-RAI-alarms-on-a-T1-1
    RAI = Remote Alarm Indication. The T1 will send RAI (also know as a Yellow alarm) when it detects a LOS/LOF on it's receive. For ESF facilities, RAI is transmitted by sending a repetitive 16-bit pattern consisting of 8 MARKS (1) followed by 8 SPACES (0) in the Datalink bits. This is transmitted for a MINIMUM of 1 second.

SBC-Gateway Series SNMP Alarms Reference ... - …

    https://www.audiocodes.com/media/15572/sbc-gateway-series-snmp-alarms-reference-guide-ver-74.pdf
    Notice Gateways&SBCs|SNMPAlarms Mediant500LGateway&E-SBCUser'sManual Mediant800Gateway&E-SBCUser'sManual Mediant1000BGateway&E-SBCUser'sManual Mediant3100Gateway&SBCUser'sManual

Solved: atlas 830 E1 connection to AudioCodes Mediant 3000 ...

    https://supportcommunity.adtran.com/t5/ATLAS-800-Series/atlas-830-E1-connection-to-AudioCodes-Mediant-3000/td-p/23190
    We are trying to connect to an AudioCodes M3K. The AudioCodes is set to: generate clock, crc4, HDB3, Network side EuroISDN. We are getting a D-channel alarm on the AudioCodes side: On the AdTran side: When we change the the "auto alarm" setting the AudioCodes sees the change and reflects the AIS or RAI so the cabling looks to be correct.

E1/T1 Line Alarms - Telephony Cards - Documentation

    https://wiki.freepbx.org/pages/viewpage.action?pageId=57411508
    wanpipemon -i w1g1 -c Ta ***** w1g1: E1 Rx Alarms (Framer) ***** ALOS: OFF | LOS: OFF RED: OFF | AIS: OFF LOF: OFF | RAI: OFF ***** w1g1: E1 Rx Alarms (LIU) ***** Short Circuit: OFF Open Circuit: OFF Loss of Signal: OFF ***** w1g1: E1 Tx Alarms ***** AIS: OFF | YEL: OFF ***** w1g1: E1 Performance Monitoring Counters ***** Line Code Violation : 330 Far End …